0.33 hp – 200 hp (0.25 kW – 132 kW) Normal
Duty
0.33 hp – 150 hp (0.25 kW – 110 kW) Heavy Duty
115 V | 208 - 240 V | 380 - 480 V
Commander variable speed drives have established
the standard of excellence in motor control since 1983 when
Control Techniques launched the first world commercial
vector drive. Since then, Commander has undergone
several successful enhancements, each time bringing new
technology and innovations to the world of automation.
The new Commander C series has been designed to be a
simple and compact AC motor speed controller that meets
advanced requirements for a wide range of applications while
optimizing the user experience.
Commander C
Highlights
✓ Set just 4 parameters to get your drive started
✓ Plug-in options for advanced control
✓ Dual Safe Torque Off (STO)
✓ Equipped with the latest energy saving features
✓ Up to 180% overload for high torque applications
✓ On board PLC
✓ Straightforward installation and commissioning
✓ Easy motor pairing and performance control
✓ Robust and reliable design |
Simple set up. 3 steps to
control
Setting up a drive can require training, specialist
knowledge and time.
But Commander C will get you up and running, from
out of the box to controlling your motor, in minutes.
Three simple steps will set up your drive for most fan,
pump, compressor, conveyor and general purpose
applications!
Commander C200 AC
Drives
Enhance throughput with machine safety, communications,
and built-in PLC
Commander C200 AC Drives
Enhance throughput with machine safety,
communications, and built-in PLC
The Commander C200 delivers benchmark
functionality at no added cost to the base drive itself.
Plug-in options, dynamic performance, PLC functionality and
other advanced features such as fieldbus, Ethernet, and
Modbus RTU communications ensure that in more complex
applications Commander C200 can deliver more than the
average general purpose drive - giving you lower cost
solutions and better productivity in your motor control
applications.
Enhance up-time and system flexibility
Flexible system integration and remote
diagnostics through optional industrial Ethernet and
fieldbus communication
Flexible I/O expandable with SI-I/O
option module
Enhanced functionality and onboard PLC
programming provides a low-cost system solution,
minimizing the need for additional equipment such as
PLCs
High performance open-loop motor control
RFC-A (Rotor Flux Control) algorithm for
exceptional induction motor control of demanding
applications
Closed loop current control without a
position feedback device
Speed control for conveyors, fans,
pumps, and mixers, where their function is controlled
remotely with fieldbus or Ethernet communication s
Key data
Heavy Duty Ratings: 0.33 hp to 150 hp
(0.25 kW to 110 kW)
Normal Duty Ratings: 0.33 hp to 200 hp
(0.25 kW to 132 kW)
Supply phases: Frame size 1 and 2: 110 V
drives 1Ø, 230 V drives 1Ø or 3Ø; Frame size 7 and
larger 3Ø; 460 V drives 3Ø
Control connections: 2x Analog inputs,
4x Digital inputs, 1x Analog output, 1x Digital I/O, 1x
Relay
Drive rating: IP21 / UL open class as
standard
Keypad: Fixed LED
Option slots: 1 (frame size 2 and above)
Parameter cloning via: PC tools, SD card
Voltage ratings
|
100 / 120 VAC ±
10% |
ü |
200 / 240 VAC ±
10% |
ü |
380 / 480 VAC ±
10% |
ü |
Control mode |
Open loop vector
or V/Hz induction motor control |
ü |
Open loop Rotor
Flux Control for
induction motors (RFC-A) |
ü |
Commander C300 AC Drives
Enhance throughput with machine safety, communications,
and built-in PLC
Commander C300 AC Drives
Commander C300 provides flexible integration
with safety and communications.
Commander C300 is ideal for applications
that require cost-effective integration into
safety systems. With two Safe Torque Off (STO)
inputs, onboard PLC and an SI interface
for industry standard fieldbuses, Ethernet
or extended I/O options, this feature set
ensures Commander C300’s flexible
integration with any system.
Enhance up-time and system flexibility
•
Flexible system integration and remote diagnostics through
optional industrial
Ethernet and fieldbus communication
•
Flexible I/O that is expandable with SI-I/O option module
•
Enhanced functionality and onboard PLC programming provides
a low-cost system
solution, minimizing the need for additional
equipment such as PLCs
High performance open loop motor control
• RFC-A
(Rotor Flux Control) algorithm for exceptional induction
motor control
of demanding applications
• Closed
loop current control without a position feedback device
• Speed
control for conveyors, fans, pumps, and mixers, where their
function
is controlled remotely with
fieldbus or Ethernet communications
Key data
Heavy Duty Ratings: 0.33 HP to 150 HP (0.25
kW to 110 kW)
Normal Duty Ratings: 0.33 HP to 200 HP (0.25
kW to 132 kW)
Supply phases: Frame size 1 and 2: 110 V
drives 1Ø,
230 V drives 1Ø or 3Ø; Frame size 7 and larger 3Ø;
460 V drives 3Ø
Control connections: 3x Analog I/O, 5x
Digital I/O, 2x STO, 1x Relay
Drive rating: IP21 / UL open class as
standard
Keypad: Fixed LED
Option slots: 1 (frame size 2 and above)
Parameter cloning via: PC tools, SD card
Voltage ratings
|
100 / 120 VAC ±
10% |
ü |
200 / 240 VAC ±
10% |
ü |
380 / 480 VAC ±
10% |
ü |
Control mode |
Open loop vector
or V/Hz induction motor control |
ü |
Open loop Rotor
Flux Control for
induction motors (RFC-A) |
ü |
-
Specifications
Control Mode
Open loop vector or V / Hz
induction motor control |
✓ |
Open loop Rotor Flux Control
for induction motors (RFC-A) |
✓ |
Environment
Ambient Operating
Temperature |
Size 1 - 4: -20°C to 40°C (-4°F to
104°F) @ 3 kHz switching freq. |
Operation to 60°C (140°F) with de-rating
Size 5 - 9: -20°C to 40°C (-4°F to
104°F) @ 3 kHz switching freq. |
Operation to 55°C (131°F) with de-rating |
Cooling Method |
Forced convection |
Humidity |
95 % non-condensing at 40 °C (104
°F) |
Storage Temperature |
Size 1 - 4: -40°C to 60°C (-40°F to
140°F) — 24 months Max.
Size 5 - 9: -40°C to 55°C (-40°F to
131°F) — 24 months Max. |
Altitude |
De-rate the continuous output
current by 1% for every 100 m (328 ft)
above 1000 m (3,280 ft) to a maximum of
3000 m (9,840 ft) |
Vibration |
Tested in accordance with IEC
60068-2-64 and IEC 60068-2-6 |
Mechanical Shock |
Tested in accordance with IEC
60068-2-27 and IEC 60068-2-29 |
Enclosure Rating |
IP20, NEMA 1 conduit kits available |
Electromagnetic Capability |
IEC/ EN 61800-3 Immunity and
Emissions
EN 61000-6-2: Immunity for industrial
environments
EN 61000-6-4: Emissions for industrial
environmentsM/br> EN 61000-3-2: Harmonic
current emissions
An EMC data sheet is available on
request |
RoHS |
Complies with the Restriction of
Hazardous Substances Directive
(2011/65/EU) |
AC
Supply Requirements
Voltage |
100 V models: 100 to 120 Vac ±10%
200 V models: 200 to 240 Vac ±10%
400 V models: 380 to 480 Vac ±10% |
Phase |
1Ø and 3Ø (Model dependent) |
Maximum Supply Imbalance |
2% negative phase sequence, 3%
voltage imbalance between phases |
Input Frequency |
45 to 66 Hz |
Input Displacement Power
Factor |
0.97 |
Control
Switching Frequency |
Size 1 - 4: 0.667, 1, 2, 3, 4, 6, 8
12 & 16 kHz
Size 5 - 9: 2, 3, 4, 6, 8 12 & 16 kHz |
Output Frequency Range |
0 to 550 Hz |
Frequency Accuracy |
±0.02% of full scale |
Frequency Resolution |
0.01 Hz |
Analog Input Resolution |
Voltage mode: 11 bits (unipolar)
Current mode: 11 bits |
Braking |
Dynamic braking transistor included,
requires external resistor |
Protection
DC Bus Under voltage Trip |
100 V models: 175 Vdc
200 V models: 175 Vdc
400 V models: 330 Vdc |
DC Bus
Overvoltage Trip |
Frame sizes 1 - 4:
100 V models: 510 Vdc
200 V models: 510 Vdc
400V models: 870 Vdc |
Frame size 5 - 9:
200V models: 415 Vdc
400 V models: 830 Vdc |
Drive Overload Trip |
Programmable: Default settings: 180%
for 3s, 150% for 60s |
Instantaneous Over current
Trip |
220% of rated motor current |
Phase Loss Trip |
DC bus ripple threshold exceeded |
Over-temperature Trip |
Drive heatsink temperature exceeds
95°C (203°F) |
Short Circuit Trip |
Protects against output
phase-to-phase fault |
Ground Fault Trip |
Protects against output
phase-to-ground fault |
Motor Thermal Trip |
Electronically protects the motor
from overheating due to loading
conditions |
Approval & Listings
UL, cUL |
UL file NMMS/8: E171230 |
CE |
CE approval |
EU |
These products comply
with the Restriction of Hazardous
Substances Directive (2011/65/EU), the
Low Voltage Directive (2014/35/EU) and
the Electromagnetic Compatibility
Directive, (2014/30/EU). |
RCM |
RCM Registered supplier
No. 12003815281 |
ISO |
Manufacturing
facilities comply with ISO 9001:2015 and
ISO 14001 |
TÜV |
C300 models only: The
Safe Torque Off (STO) function may be
used as a safety component of a machine.
Type examination certificates by TÜV
Rheinland:
Frame sizes 1 - 4: No. 01/205/5383.03/18
Frame sizes 5 - 9: No. 01/205/5387.02/18
Functional safety parameters:
EN ISO 13849-1 - Cat 4, PLe
EN61800-5-2/EN62061/IEC 61508 - SIL 3
UL functional safety approval: FSPC
E171230 |
-
Applications
Whatever your application,
Commander C is the perfect solution across
industries
The Commander series are simple and
compact AC motor speed controllers that meet
advanced requirements in a wide range of
applications. Their small footprint – among the
smallest in their class – makes them ideal for
machine builders and OEMs, where space is at a
premium.
-
Options
Keypads
|
Remote Keypad RTC
The keypad is remote mountable, allowing
flexible mounting on the outside of a
panel (meets IP54/NEMA 12). Three line
plain text, multi-language LCD keypad
for rapid set-up and helpful
diagnostics. Battery operated real-time
clock allows accurate time stamping of
events, aiding diagnostics. |
|
Remote Keypad
Remote mountable, intuitive plain text,
multilingual LCD keypad for rapid set-up
and superior diagnostics (using the
AI-485 adaptor along with a comms lead).
Rapid and secure panel fit with 1 x 32mm
hole rated to IP66 (NEMA 4). |
System Integration Modules - Communications
|
SI-PROFIBUS
SI-PROFIBUS interface module enables
follower connectivity. It is possible to
use multiple SI-PROFIBUS modules or a
combination of SI-PROFIBUS and other
option module types to add additional
functionality such as extended I/O,
gateway functionality or additional PLC
features. |
|
SI-DeviceNet
SI-DeviceNet enables follower
connectivity. It is possible to use
multiple SI-DeviceNet modules to provide
additional functionality. |
|
SI-CANopen
Commander C's SI-CANopen interface
module supports various profiles,
offering optimum flexibility. |
|
SI-Ethernet
SI-Ethernet can be used to provide high
speed drive access, global connectivity
and integration with IT network
technologies. |
|
SI-EtherCAT
SI-EtherCAT allows Commander C general
purpose drive to connect and interface
with EtherCAT networks. |
|
SI-PROFINET-V2
SI-PROFINET-V2 allows Commander C to
communicate and interface with PROFINET
PLCs and networks. |
System Integration Modules - Additional I/O
|
SI-I/O Extended
I/O interface module to increase the
number of I/O points on a drive.
Provides additional: 4 x Digital I/O, 3
x Analog inputs (default)/Digital
inputs, 1 x Analog output
(default)/Digital input, 2 x Relays. |
Optional Accessories
|
AI-Back-up Adaptor
Port adaptor for SD card parameter
cloning, and an input for 24 V back-up. |
|
AI-Smart Adaptor Has
a built-in memory for parameter cloning
and an input for 24 V back-up. |
|
AI-485 Adaptor
Adaptor that allows the drive to
communicate via RS485. |
|
AI-485 24 V Adaptor
Adaptor with 24 V input. |
|
RS485 Cable The USB
comms cable allows the drive to connect
to a PC for use with Commander's PC
tools. |
-
Software & Support
Intuitive commissioning software
|
Connect -
Commissioning tool
Based on Control Techniques’ 25 years'
experience, Connect is our latest drive
configuration tool for commissioning,
optimizing and monitoring drive/system
performance.
|
Advanced machine control
|
Machine Control Studio -
Programming tool
Control Techniques' Machine Control
Studio provides a flexible and intuitive
environment for programming Commander C’s
new automation and motion control features.
|
Diagnostics Tool
|
Diagnostic Tool
Diagnostic Tool is a fast and simple
tool, which allows users of Control
Techniques' drives to quickly solve any
error codes that the drive may show.
|
Drive Setup
|
Drive Setup
Free access web pages provide
‘how-to’ videos, step by step guides and
comprehensive technical manuals for your
drive installation.
|
|